Zobrazit minimální záznam
dc.contributor.advisor |
Syrový, Tomáš |
cze |
dc.contributor.author |
Foltanovičová, Gabriela
|
|
dc.date.accessioned |
2015-08-10T07:46:53Z |
|
dc.date.available |
2015-08-10T07:46:53Z |
|
dc.date.issued |
2015 |
|
dc.identifier |
Univerzitní knihovna (studovna) |
cze |
dc.identifier.uri |
http://hdl.handle.net/10195/60515 |
|
dc.description.abstract |
Táto diplomová práca sa zaoberá zobrazením farieb na dvoch monitoroch EIZO a ich vnímaním
radou pozorovateľov. Teoretická časť sa zaoberá správou farieb a jej zložkami, popisom
vyjadrenia gamutov zariadení a štandardizovanými farbovými priestormi. Ďalej je popísaná
technológia LCD monitorov, ich kalibrácia a profilácia a taktiež sú uvedené pozorovacie
podmienky určené medzinárodnými štandardami ISO. Záver teoretickej časti je zameraný
na psychofyzikálne experimenty.
V experimentálnej časti je kladený dôraz na popis prípravy a priebehu psychofyzikálneho
experimentu, v ktorom boli využité dva monitory s LED podsvietením odlišujúcich sa v rozsahu
reprodukovaných farieb (sRGB, Adobe RGB). Cieľom experimentu bolo vyhodnotenie
subjektívneho pozorovania farbových odchýlok na týchto monitoroch, pričom kolorimetrická
charakteristika porovnávaných farieb bola skoro totožná. Z nameraných a zistených dát boli
získané výsledky, na základe ktorých nebolo potvrdené, že vnímanie farieb je závislé najmä
na odtieni farby. Najväčšia závislosť vnímanej odchýlky a parametru farby bola preukázaná
na mernej svetlosti (L*). Pre modré a červené farby bola tiež mierna závislosť na chrome farby. |
slo |
dc.format |
99 s. |
|
dc.format.extent |
5271105 bytes |
cze |
dc.format.mimetype |
application/pdf |
cze |
dc.language.iso |
slo |
|
dc.publisher |
Univerzita Pardubice |
cze |
dc.rights |
Práce není přístupná |
cze |
dc.subject |
color |
cze |
dc.subject |
color perception |
cze |
dc.subject |
LCD monitor |
cze |
dc.subject |
gamut |
cze |
dc.subject |
farba |
slo |
dc.subject |
vnem farby |
slo |
dc.title |
Porovnání zobrazení na různých monitorech EIZO |
cze |
dc.title.alternative |
Comparison of colour rendering on EIZO displays |
eng |
dc.type |
diplomová práce |
cze |
dc.contributor.referee |
Dzik, Petr |
cze |
dc.date.accepted |
2015 |
cze |
dc.description.abstract-translated |
This master thesis deals with displaying colors on two EIZO monitors and their perception
by observers. In the theoretical part first the color management and its components, device
color gamuts and standard color spaces are described. Technology of LCD monitors, its calibration
and profiling, and observing conditions set by ISO international standards are also
mentioned. End of the theoretical part is focused on psychophysical experiments.
The experimental part is focused on the description of preparation and process of psychophysical
experiment. Two monitors with LED backlight, varying in gamut (sRGB, Adobe
RGB) were used. The aim of that experiment was to evaluate subjective observations of a color
differences on these two monitors. The colorimetric characteristics of the color were almost
identical. Based on measured and observed data, were obtained the result, that perception
of color does not depend on hue of the color. The biggest dependence between percieved
difference and color parameter was proved for lightness (L*). For the blue and red colors there
is also a slight dependence on chroma. |
eng |
dc.description.department |
Katedra polygrafie a fotofyziky |
cze |
dc.thesis.degree-discipline |
Polygrafie |
cze |
dc.thesis.degree-name |
Ing. |
cze |
dc.thesis.degree-grantor |
Univerzita Pardubice. Fakulta chemicko-technologická |
cze |
dc.identifier.signature |
D32201 |
cze |
dc.thesis.degree-program |
Polygrafie |
cze |
dc.description.defence |
doc. Ing. Petr Němec, Ph.D.: Jak velký barevný Gamut lze očekávat od velkoplošných obrazovek? Byla nějak zhodnocena spolehlivost měření použitých kolorimetrem? Má volba pozorovatelů podle jednotlivých kategorií nějakou vypovídací hodnotu?
doc. Ing. Michal Veselý, CSc.: Co jste testovala-pozorovatele nebo monitory? Byl rozdíl mezi běžnými pozorovateli a zkušenými pozorovateli? Jaké bylo osvětlení v místnosti, kde se hodnocení provádělo? |
cze |
dc.identifier.stag |
27176 |
cze |
dc.date.embargo |
2035-05-07 |
cze |
dc.description.grade |
Dokončená práce s úspěšnou obhajobou |
cze |
Tento záznam se objevuje v následujících kolekcích
Zobrazit minimální záznam
|
Vyhledávání
Procházet
-
Vše v Digitální knihovně
-
Tato kolekce
Můj účet
|